Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Echocardiography ; 41(2): e15765, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38341768

RESUMO

BACKGROUND: Mixed pulmonary disease with pulmonary regurgitation (PR) and stenosis (PS) in repaired tetralogy of Fallot (rTOF) can negatively impact ventricular health. Myocardial strain has been shown to be more sensitive at detecting occult ventricular dysfunction compared to right ventricular ejection fraction (RV EF). We hypothesize that rTOF patients with predominant PS will have lower RV global longitudinal strain (RV GLS) prior to and post-transcatheter pulmonary valve replacement (TPVR). METHODS: A retrospective cohort of rTOF patients who underwent cardiac magnetic resonance (CMR) and cardiac catheterization for right ventricular pressure (RVSP) measurement were analyzed at three time points: before valve implantation, at discharge and within 18 months post-TPVR. Patients were dichotomized into three groups based on RVSP: 0%-49%, 50%-74%, and >75%. RV GLS and left ventricular (LV) GLS by speckle tracking echocardiography (STE) were obtained from the apical 4-chamber using TomTec software (TOMTEC IS, Germany). RESULTS: Forty-eight patients were included. Every 14.3% increase in preimplantation RVSP above 28% was associated with an absolute magnitude 1% lower RV GLS (p = .001). Preimplantation RVSP when 75% or higher had 3.36% worse RV GLS than the lowest bin (p = .014). Overall, average RV strain magnitude was higher when preimplantation RVSP was less than 50% and had greater improvement over the three time points. Higher post implantation RVSP correlated with lower strain magnitude. CONCLUSION: Patients with significant PS (>50%) may benefit from earlier PVR and not depend solely on RV size and EF. Myocardial strain may be a more sensitive marker of function; however, larger, prospective studies are needed.


Assuntos
Insuficiência da Valva Pulmonar , Estenose da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Disfunção Ventricular Direita , Humanos , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Deformação Longitudinal Global , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Direita , Estenose da Valva Pulmonar/complicações , Estenose da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/complicações , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/diagnóstico por imagem
2.
JTCVS Open ; 15: 433-445, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37808023

RESUMO

Objectives: Palliative treatment of cyanotic congenital heart disease (CCHD) uses systemic-to-pulmonary conduits, often a modified Blalock-Taussig-Thomas shunt (mBTTs). Expanded polytetrafluoroethylene (ePTFE) mBTTs have associated risks for thrombosis and infection. The Human Acellular Vessel (HAV) (Humacyte, Inc) is a decellularized tissue-engineered blood vessel currently in clinical trials in adults for vascular trauma, peripheral artery disease, and end-stage renal disease requiring hemodialysis. In addition to restoring blood flow, the engineered HAV demonstrates the capacity for host cellular remodeling into native-like vasculature. Here we report preclinical evaluation of a small-diameter (3.5 mm) HAV as a mBTTs in a non-human primate model. Methods: We implanted 3.5 mm HAVs as right subclavian artery to pulmonary artery mBTTs in non-immunosuppressed juvenile rhesus macaques (n = 5). HAV patency, structure, and blood flow were assessed by postoperative imaging from 1 week to 6 months. Histology of HAVs and surrounding tissues was performed. Results: Surgical procedures were well tolerated, with satisfactory anastomoses, showing feasibility of using the 3.5 mm HAV as a mBTTs. All macaques had some immunological reactivity to the human extracellular matrix, as expected in this xenogeneic model. HAV mBTTs remained patent for up to 6 months in animals, exhibiting mild immunoreactivity. Two macaques displaying more severe immunoreactivity to the human HAV material developed midgraft dilatation without bleeding or rupture. HAV repopulation by host cells expressing smooth muscle and endothelial markers was observed in all animals. Conclusions: These findings may support use of 3.5 mm HAVs as mBTTs in CCHD and potentially other pediatric vascular indications.

3.
JACC Cardiovasc Interv ; 16(15): 1917-1928, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37278682

RESUMO

BACKGROUND: The Harmony transcatheter pulmonary valve (TPV) is the first U.S. Food and Drug Administration-approved device for severe pulmonary regurgitation (PR) in the native or surgically repaired right ventricular outflow tract (RVOT). OBJECTIVES: One-year safety and effectiveness of the Harmony TPV were evaluated in patients from the Harmony Native Outflow Tract Early Feasibility Study, Harmony TPV Pivotal Study, and Continued Access Study, representing the largest cohort to date of Harmony TPV recipients. METHODS: Eligible patients had severe PR by echocardiography or PR fraction ≥ 30% by cardiac magnetic resonance imaging and clinical indications for pulmonary valve replacement. The primary analysis included 87 patients who received a commercially available TPV22 (n = 42) or TPV25 (n = 45) device; 19 patients who received an early device iteration prior to its discontinuation were evaluated separately. RESULTS: In the primary analysis, median patient age at treatment was 26 years (IQR: 18-37 years) in the TPV22 group and 29 years (IQR: 19-42 years) in the TPV25 group. At 1 year, there were no deaths; 98% of TPV22 and 91% of TPV25 patients were free from the composite of PR, stenosis, and reintervention (moderate or worse PR, mean RVOT gradient >40 mmHg, device-related RVOT reoperation, and catheter reintervention). Nonsustained ventricular tachycardia occurred in 16% of patients. Most patients had none/trace or mild PR (98% of TPV22 patients, 97% of TPV25 patients). Outcomes with the discontinued device are reported separately. CONCLUSIONS: The Harmony TPV device demonstrated favorable clinical and hemodynamic outcomes across studies and valve types through 1 year. Further follow-up will continue to assess long-term valve performance and durability.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Obstrução do Fluxo Ventricular Externo , Humanos , Cateterismo Cardíaco , Estudos Prospectivos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/etiologia
4.
JTCVS Open ; 13: 330-343, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37063164

RESUMO

Objective: Pulmonary artery reconstruction during comprehensive stage 2 (CS2) procedure can be challenging. Since 2017, we have employed preemptive left pulmonary artery (LPA) stenting. We hypothesized that LPA stenting promotes adequate growth and without compromising Fontan candidacy. Herewith, we report our midterm results. Methods: From 2002 to 2020, 159 patients underwent CS2. Patients were divided as follows: no stent (n = 122; Group 1) and perioperative LPA stent (n = 37; Group 2). Group 2 was subdivided according to unplanned stent (n = 17; Group 2a) or preemptive stent (n = 20; Group 2b). Relevant perioperative data was reviewed. Nonparametric statistics were utilized. Results: Median age and weight at surgery and hospital length of stay after CS2 did not differ between groups. Median cardiopulmonary bypass and crossclamp times were significantly greater in Group 1 (265 vs 243 minutes [P = .021] and 46 vs 26 minutes [P = .008]). In-hospital mortality was similar between Groups 1 and 2 (9.0% vs 18.9%, respectively [P = .1348]). Group 2b demonstrated a superior survival compared to Group 2a (P = .0335) but not Group 1 (P > .9999). Preemptive stenting significantly increased median hilar LPA diameter at CS2 exit angiogram compared with no stenting (P < .0001). Groups 2a and 2b significantly increased the pre-Fontan diameter of the hilar LPA when compared with Group 1 (6.1 and 6.8 vs 5.7 mm, respectively [P < .0001]). A further 120 patients underwent Fontan operation (75%). Median follow-up for Groups 1 and 2 were 7.4 and 3.0 years, respectively. Conclusions: Perioperative LPA stenting during CS2 does not adversely affect pulmonary growth. Preemptive stenting seems advantageous for LPA growth in preparation for Fontan completion.

5.
Pediatr Cardiol ; 44(6): 1406-1413, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36995404

RESUMO

To evaluate short-term procedural outcomes and safety for infants < 2.5 kg who underwent catheterization with intended patent ductus arteriosus (PDA) device closure in a multi-center registry, as performance of this procedure becomes widespread. A multi-center retrospective review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes (C3PO) registry. Data were collected for all intended cases of PDA closure in infants < 2.5 kg from April 2019 to December 2020 at 13 participating sites. Successful device closure was defined as device placement at the conclusion of the catheterization. Procedural outcomes and adverse events (AE) were described, and associations between patient characteristics, procedural outcomes and AEs were analyzed. During the study period, 300 cases were performed with a median weight of 1.0 kg (range 0.7-2.4). Successful device closure was achieved in 98.7% of cases with a 1.7% incidence of level 4/5 AEs, including one periprocedural mortality. Neither failed device placement nor adverse events were significantly associated with patient age, weight or institutional volume. Higher incidence of adverse events associated with patients who had non-cardiac problems (p = 0.017) and cases with multiple devices attempted (p = 0.064). Transcatheter PDA closure in small infants can be performed with excellent short-term outcomes and safety across institutions with variable case volume.


Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Lactente , Humanos , Permeabilidade do Canal Arterial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Sistema de Registros , Fatores de Tempo , Estudos Retrospectivos
6.
Pediatr Cardiol ; 44(4): 795-805, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36806971

RESUMO

Data on the frequency and outcome of surgical interventions as a result of adverse events (AE) encountered in the pediatric and congenital cardiac catheterization laboratory are limited. This study analyzes the outcomes of specific types of AE that are most likely to require immediate surgical intervention. Data from the C3PO registry were analyzed to identify specific types of significant vascular/cardiac trauma or technical adverse events (stent/device/coil embolization/migration). The relationship between these AE and an "adverse outcome" (defined as either surgery, ECMO, or death) were analyzed. Between 01/2014 and 12/2017, 25,731 cases were entered into the C3PO registry. Vascular or cardiac trauma were observed in 92 cases (0.36% cases in C3PO), and technical adverse events were observed in 176 cases (0.68% cases in C3PO). The two highest procedure type risk categories (PREDIC3T) accounted for 61% of the cases in the cardiac/vascular trauma cohort, and 34% in the technical AE cohort. For vascular/cardiac trauma, 24 (26%) had an adverse outcome, with ECMO in 8 (9%), surgery in 19 (20%), and death in 9 (10%). For technical AE 25 (14%) had an adverse outcome, with ECMO in 3 (2%), surgery in 23 (13%), and death in 3 (2%). Survival after cardiac surgery secondary to an AE was 68% for cardiac/vascular trauma, and 96% for technical adverse events. RF perforation of the pulmonary valve was the procedure most likely to result in cardiac/vascular trauma (10%), with 57% of those having an adverse outcome. Atrial septal interventions accounted for 29% of all adverse outcomes in the cardiac/vascular trauma cohort. Non-elective or emergent cases were associated with a significantly higher incidence of an adverse outcome for both, cardiac/vascular trauma (OR 7.1) and technical adverse events (OR 2.7). Surgery within the last 30 days was associated with a significantly higher incidence of an adverse outcome for cardiac/vascular trauma only (OR 4.2). Significant cardiac/vascular trauma or stent/device/coil embolization/migration are rare, but high consequence AE. With appropriate surgical and ECMO backup, a high survival can be achieved. The potential need for and impact of immediate surgical backup seems to be higher for cardiac/vascular trauma (in particular after specific case types), than for device/coil migration/embolization, and as such case specific backup arrangements are required.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Valva Pulmonar , Cirurgia Torácica , Criança , Humanos , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Resultado do Tratamento , Fatores de Risco
7.
Heart ; 109(9): 710-718, 2023 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-36598072

RESUMO

OBJECTIVE: As COVID-19 continues to affect the global population, it is crucial to study the impact of the disease in vulnerable populations. This study of a diverse, international cohort aims to provide timely, experiential data on the course of disease in paediatric patients with congenital heart disease (CHD). METHODS: Data were collected by capitalising on two pre-existing CHD registries, the International Quality Improvement Collaborative for Congenital Heart Disease: Improving Care in Low- and Middle-Income Countries and the Congenital Cardiac Catheterization Project on Outcomes. 35 participating sites reported data for all patients under 18 years of age with diagnosed CHD and known COVID-19 illness during 2020 identified at their institution. Patients were classified as low, moderate or high risk for moderate or severe COVID-19 illness based on patient anatomy, physiology and genetic syndrome using current published guidelines. Association of risk factors with hospitalisation and intensive care unit (ICU) level care were assessed. RESULTS: The study included 339 COVID-19 cases in paediatric patients with CHD from 35 sites worldwide. Of these cases, 84 patients (25%) required hospitalisation, and 40 (12%) required ICU care. Age <1 year, recent cardiac intervention, anatomical complexity, clinical cardiac status and overall risk were all significantly associated with need for hospitalisation and ICU admission. A multivariable model for ICU admission including clinical cardiac status and recent cardiac intervention produced a c-statistic of 0.86. CONCLUSIONS: These observational data suggest risk factors for hospitalisation related to COVID-19 in paediatric CHD include age, lower functional cardiac status and recent cardiac interventions. There is a need for further data to identify factors relevant to the care of patients with CHD who contract COVID-19 illness.


Assuntos
COVID-19 , Cardiopatias Congênitas , Humanos , Criança , Adolescente , COVID-19/epidemiologia , COVID-19/complicações , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/terapia , Cardiopatias Congênitas/complicações , Unidades de Terapia Intensiva , Fatores de Risco
8.
Pediatr Cardiol ; 44(1): 132-140, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36029321

RESUMO

The aim of the study was to determine the variables associated with high-quality (HQ) versus low-quality (LQ) three-dimensional rotational angiography (3DRA) and create guides for optimization of approach to 3DRA in congenital cardiac catheterization (CCC). CCC has adopted 3DRA as a mainstay, but there has not been systematic analysis of approach to and factors associated with HQ 3DRA. This was a single-center, retrospective study of 3DRAs using Canon Infinix-I platform. Reconstructions were graded by 3 interventionalists. Quality was dichotomized into HQ and LQ. Univariable analyses and multivariable logistic regression models were performed. From 8/2016 to 12/2018, 208 3DRAs were performed in 195 CCCs; median age 7 years (2, 16), weight 23 kg (12, 57). The majority of 3DRAs were performed in patients with biventricular physiology (N = 137, 66%) and in pulsatile sites (N = 144, 69%). HQ 3DRA (N = 182, 88%) was associated with greater total injection volume [2.20 mL/kg (1.44, 3.29) vs. 1.62 mL/kg (1.10, 1.98), p = 0.005] and more dilute contrast solution [60% (50, 100) vs. 100% (60, 100), p = 0.007], but not with contrast volume administered (p = 0.2) on univariable analysis. On multivariable logistic regression, HQ 3DRA was significantly associated with patient weight [OR 0.97 (95% CI (0.94, 0.99), p = 0.018], total injection volume [OR 1.04 (95% CI 1.01, 1.07) p = 0.011], and percent contrast solution [OR 0.97 (95% CI 0.95, 1.00), p = 0.022]. These data resulted in creation of scatter plots and a novel 3DRA Nomogram for estimating the probability of HQ 3DRA. This is the first study to create evidence-based contrast dose guides and nomogram for 3DRA in CCC. HQ 3DRA was associated with lower weight, higher total injection volumes, and more dilute contrast solution.


Assuntos
Imageamento Tridimensional , Procedimentos de Cirurgia Plástica , Humanos , Criança , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Angiografia/métodos , Cateterismo Cardíaco/métodos
9.
JACC Adv ; 1(5): 100143, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36471862

RESUMO

Background: The COVID-19 pandemic has posed tremendous stress on the health care system. Its effects on pediatric/congenital catheterization program practice and performance have not been described. Objectives: The purpose of this study was to evaluate how case volumes, risk-profile, and outcomes of pediatric/congenital catheterization procedures changed in response to the first wave of COVID-19 and after that wave. Methods: A multicenter retrospective observational study was performed using Congenital Cardiac Catheterization Project on Outcomes Registry (C3PO) data to study changes in volume, case mix, and outcomes (high-severity adverse events [HSAEs]) during the first wave of COVID (March 1, 2020, to May 31, 2020) in comparison to the period prior to (January 1, 2019, to February 28, 2020) and after (June 1, 2020, to December 31, 2020) the first wave. Multivariable analyses adjusting for case type, hemodynamic vulnerability, and age group were performed. Hospital responses to the first wave were captured with an electronic study instrument. Results: During the study period, 12,557 cases were performed at 14 C3PO hospitals (with 8% performed during the first wave of COVID and 32% in the postperiod). Center case volumes decreased from a median 32.1 cases/month (IQR: 20.7-49.0 cases/month) before COVID to 22 cases/month (IQR: 13-31 cases/month) during the first wave (P = 0.001). The proportion of cases with risk factors for HSAE increased during the first wave, specifically proportions of infants and neonates (P < 0.001) and subjects with renal insufficiency (P = 0.02), recent cardiac surgery (P < 0.001), and a higher hemodynamic vulnerability score (P = 0.02). The observed HSAE risk did not change significantly (P = 0.13). In multivariable analyses, odds of HSAE during the first wave of COVID (odds ratio: 0.75) appeared to be lower than that before COVID, but the difference was not significant (P = 0.09). Conclusions: Despite increased case-mix complexity, C3PO programs maintained, if not improved, their performance in terms of HSAE. Exploratory analyses of practice changes may inform future harm-reduction efforts.

10.
Extracell Vesicle ; 12022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36330420

RESUMO

Patients with single ventricle heart defects requires a series of staged open-heart procedures, termed Fontan palliation. However, while lifesaving, these operations are associated with significant morbidity and early mortality. The attendant complications are thought to arise in response to the abnormal hemodynamics induced by Fontan palliation, although the pathophysiology underlying these physicochemical changes in cardiovascular and other organs remain unknown. Here, we investigated the microRNA (miRNA) content in serum and serum-derived extracellular vesicles (EVs) by sequencing small RNAs from a physiologically relevant sheep model of the Fontan operation. The differential expression analysis identified the enriched miRNA clusters in (1) serum vs. serum-derived EVs and (2) pre-Fontan EVs vs. post-Fontan EVs. Metascape analysis showed that the overexpressed subset of EV miRNAs by Fontan procedure target liver-specific cells, underscoring a potentially important pathway involved in the liver dysfunction that occurs as a consequence of Fontan palliation. We also found that post-Fontan EV miRNAs were associated with senescence and cell death, whereas pre-Fontan EV miRNAs were associated with stem cell maintenance and epithelial-to-mesenchymal transition. This study shows great potential to identify novel circulating EV biomarkers from Fontan sheep serum that may be used for the diagnosis, prognosis, and therapeutics for patients that have undergone Fontan palliation.

11.
Mol Ther Methods Clin Dev ; 27: 47-60, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36186954

RESUMO

In a phase 1/2, open-label dose escalation trial, we delivered rAAVrh74.MCK.GALGT2 (also B4GALNT2) bilaterally to the legs of two boys with Duchenne muscular dystrophy using intravascular limb infusion. Subject 1 (age 8.9 years at dosing) received 2.5 × 1013 vector genome (vg)/kg per leg (5 × 1013 vg/kg total) and subject 2 (age 6.9 years at dosing) received 5 × 1013 vg/kg per leg (1 × 1014 vg/kg total). No serious adverse events were observed. Muscle biopsy evaluated 3 or 4 months post treatment versus baseline showed evidence of GALGT2 gene expression and GALGT2-induced muscle cell glycosylation. Functionally, subject 1 showed a decline in 6-min walk test (6MWT) distance; an increase in time to run 100 m, and a decline in North Star Ambulatory Assessment (NSAA) score until ambulation was lost at 24 months. Subject 2, treated at a younger age and at a higher dose, demonstrated an improvement over 24 months in NSAA score (from 20 to 23 points), an increase in 6MWT distance (from 405 to 478 m), and only a minimal increase in 100 m time (45.6-48.4 s). These data suggest preliminary safety at a dose of 1 × 1014 vg/kg and functional stabilization in one patient.

12.
Cardiol Ther ; 11(4): 523-530, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36074260

RESUMO

INTRODUCTION: Guidelines recommend lifelong follow-up with transthoracic echocardiograms (TTE) for patients who had a patent ductus arteriosus (PDA) device closure via catheterization. The goal of this study was to determine the utility of follow-up TTE in patients who underwent an uncomplicated PDA device closure during infancy. METHODS: Chart review was performed on patients who had a PDA closure at not more than 1 year of age between January 1, 2002 and June 1, 2020. Patients were excluded if they had other congenital heart disease, did not have a follow-up TTE at least 3 months after procedure, or had a velocity greater than 2.0 m/s in the left pulmonary artery (LPA) or descending aorta (DAo) on the first TTE at least 3 months after device placement. Time points included the first TTE after the procedure, first TTE at least 3 months after procedure, and the most recent TTE. RESULTS: Total of 147 infants met the inclusion criteria. Age and weight at initial procedure were 141 ± 217 days and 4.2 ± 2.8 kg. There was no significant difference in DAo velocity between initial and most recent TTE. LPA velocity and left ventricular diastolic Z score significantly decreased between initial and most recent TTE. Seventy-eight patients had repeat echocardiograms more than 1 year after PDA procedure with no change in clinical management. No patient underwent an intervention on the LPA or DAo for stenosis. CONCLUSION: In patients who underwent an uncomplicated PDA closure during infancy, TTE parameters either stayed stable or improved over time. These findings need to be corroborated in larger studies with longer follow-up. If verified, the long-term TTE guidelines may need to be simplified for this patient population.

13.
Cardiol Ther ; 11(3): 445-452, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35780440

RESUMO

INTRODUCTION: Guidelines recommend lifelong follow-up with transthoracic echocardiograms (TTE) for patients who had a patent ductus arteriosus (PDA) device closure via catheterization. The goal of this study was to determine the utility of follow-up TTE in patients who underwent an uncomplicated PDA device closure after infancy. METHODS: Chart review was performed on patients who had a PDA closure ≥ 1 year of age between 1/1/2002 and 6/1/2020. Patients were excluded if they had other congenital heart disease, did not have a follow-up TTE ≥ 6 months after procedure, had a residual PDA or velocity > 2.0 m/s in the left pulmonary artery (LPA) or descending aorta (DAo) on the first TTE ≥ 6 months after device placement. Time points included the initial TTE after the procedure, first TTE ≥ 6 months after procedure, and the most recent TTE. RESULTS: A total of 189 patients met the study criteria. The median age and weight at initial procedure were 2.7 (1.0-64.7) years and 12.5 (3.4-69.2) kg. Most recent TTE was performed 2.0 (0.4-17.0) years after PDA closure. There were no significant differences in fractional shortening (36.4 ± 5.0% vs. 36.9 ± 5.6%) or LPA velocity (1.1 ± 0.4 m/s vs. 1.1 ± 0.4 m/s) from initial to most recent TTE, respectively. Left ventricular internal diastolic diameter Z-score significantly decreased (1.4 ± 1.8 vs. - 0.01 ± 1.2, p < 0.01) and DAo peak velocity significantly increased (1.2 ± 0.3 m/s vs. 1.3 ± 0.3 m/s, p = 0.02) from initial to most recent TTE, respectively. No patient died or underwent an intervention on the LPA or DAo for stenosis. Seventy-five patients had a total of 208 repeat TTE > 1 year after PDA procedure with no change in clinical management. CONCLUSIONS: In patients who underwent an uncomplicated PDA closure after infancy, TTE parameters improved or stayed within normal limits on the most recent TTE. Repeat lifetime TTEs after 1-year post-device placement in this population may not necessarily be needed if there are no clinical concerns.

14.
JACC Cardiovasc Interv ; 15(9): 979-988, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35512922

RESUMO

OBJECTIVES: The aim of this study was to evaluate the accuracy of cardiac magnetic resonance (CMR) in predicting coronary artery (CA) compression during transcatheter pulmonary valve implantation (TPVi). BACKGROUND: TPVi is a widely available option to treat dysfunctional right ventricle (RV)-to-pulmonary artery (PA) conduits, but CA compression is an absolute contraindication. CMR can evaluate coronary anatomy, but its utility in predicting CA compression is not well established. METHODS: After Institutional Review Board approval was obtained, all patients at 9 centers with attempted TPVi in RV-PA conduits and recent CMR (≤12 months) were analyzed. A core laboratory reviewed all CMR studies for the shortest orthogonal distance from a CA to the conduit, the shortest distance from a CA to the most stenotic area of the conduit, and subjective assessment of CA compression risk. RESULTS: Among 231 patients, TPVi was successful in 198 (86%); in 24 (10%), balloon testing precluded implantation (documented CA compression or high risk). Distance to the RV-PA conduit ≤2.1 mm (area under the curve [AUC]: 0.70) and distance to most stenotic area ≤13.1 mm (AUC: 0.69) predicted CA compression. Subjective assessment had the highest AUC (0.78), with 96% negative predictive value. Both distances and qualitative assessment remained independently associated with CA compression when controlling for abnormal coronary anatomy or degree of conduit calcification. CONCLUSIONS: CMR can help predict the risk for CA compression during TPVi in RV-PA conduits but cannot completely exclude CA compression. CMR may assist in patient selection and counseling families prior to TPVi, although balloon testing remains essential.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Cateterismo Cardíaco/efeitos adversos , Vasos Coronários , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Espectroscopia de Ressonância Magnética , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
15.
Commun Med (Lond) ; 2: 3, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35603301

RESUMO

Background: Tissue-engineered vascular grafts (TEVGs) have the potential to advance the surgical management of infants and children requiring congenital heart surgery by creating functional vascular conduits with growth capacity. Methods: Herein, we used an integrative computational-experimental approach to elucidate the natural history of neovessel formation in a large animal preclinical model; combining an in vitro accelerated degradation study with mechanical testing, large animal implantation studies with in vivo imaging and histology, and data-informed computational growth and remodeling models. Results: Our findings demonstrate that the structural integrity of the polymeric scaffold is lost over the first 26 weeks in vivo, while polymeric fragments persist for up to 52 weeks. Our models predict that early neotissue accumulation is driven primarily by inflammatory processes in response to the implanted polymeric scaffold, but that turnover becomes progressively mechano-mediated as the scaffold degrades. Using a lamb model, we confirm that early neotissue formation results primarily from the foreign body reaction induced by the scaffold, resulting in an early period of dynamic remodeling characterized by transient TEVG narrowing. As the scaffold degrades, mechano-mediated neotissue remodeling becomes dominant around 26 weeks. After the scaffold degrades completely, the resulting neovessel undergoes growth and remodeling that mimicks native vessel behavior, including biological growth capacity, further supported by fluid-structure interaction simulations providing detailed hemodynamic and wall stress information. Conclusions: These findings provide insights into TEVG remodeling, and have important implications for clinical use and future development of TEVGs for children with congenital heart disease.

16.
Cardiol Young ; 32(12): 1952-1956, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35152927

RESUMO

BACKGROUND: Recurrent laryngeal nerve injury leading to vocal cord paralysis is a known complication of cardiothoracic surgery. Its occurrence during interventional catheterisation procedures has been documented in case reports, but there have been no studies to determine an incidence. OBJECTIVE: To establish the incidence of left recurrent laryngeal nerve injury leading to vocal cord paralysis after left pulmonary artery stenting, patent ductus arteriosus device closure and the combination of the procedures either consecutively or simultaneously. METHODS: Members of the Congenital Cardiovascular Interventional Study Consortium were asked to perform a retrospective analysis to identify cases of recurrent laryngeal nerve injury after the aforementioned procedures. Twelve institutions participated in the analysis. They also contributed the total number of each procedure performed at their respective institutions for statistical purposes. RESULTS: Of the 1337 patients who underwent left pulmonary artery stent placement, six patients (0.45%) had confirmed vocal cord paralysis. 4001 patients underwent patent ductus arteriosus device closure, and two patients (0.05%) developed left vocal cord paralysis. Patients who underwent both left pulmonary artery stent placement and patent ductus arteriosus device closure had the highest incidence of vocal cord paralysis which occurred in 4 of the 26 patients (15.4%). Overall, 92% of affected patients in our study population had resolution of symptoms. CONCLUSION: Recurrent laryngeal nerve injury is a rare complication of left pulmonary artery stent placement or patent ductus arteriosus device closure. However, the incidence is highest in patients undergoing both procedures either consecutively or simultaneously. Additional research is necessary to determine contributing factors that might reduce the risk of recurrent laryngeal nerve injury.


Assuntos
Permeabilidade do Canal Arterial , Traumatismos do Nervo Laríngeo Recorrente , Paralisia das Pregas Vocais , Humanos , Traumatismos do Nervo Laríngeo Recorrente/etiologia , Traumatismos do Nervo Laríngeo Recorrente/complicações , Paralisia das Pregas Vocais/epidemiologia , Paralisia das Pregas Vocais/etiologia , Permeabilidade do Canal Arterial/epidemiologia , Permeabilidade do Canal Arterial/cirurgia , Permeabilidade do Canal Arterial/complicações , Incidência , Estudos Retrospectivos , Cateterismo/efeitos adversos
17.
Pediatr Cardiol ; 43(3): 596-604, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34743224

RESUMO

The objective of this study was to evaluate the impact of the regular introduction of new technologies into interventional cardiac catheterization procedures, in this case new atrial septal defect (ASD) closure devices, while conducting a multi-center collaborative initiative to reduce radiation usage during all procedures. Data were collected prospectively by 8 C3PO institutions between January 1, 2014 and December 31, 2017 for ASD device closure procedures in the cardiac catheterization lab during a quality improvement (QI) initiative aimed at reducing patient radiation exposure. Radiation exposure was measured in dose area product per body weight (µGy*m2/kg). Use of proposed practice change strategies at the beginning and end of the QI intervention period was assessed. Radiation exposure was summarized by institution and by initial type of device used for closure. This study included 602 ASD device closures. Without changes in patient characteristics, total fluoroscopy duration, or number of digital acquisitions, median radiation exposure decreased from 37 DAP/kg to 14 DAP/kg from 2014 to 2017. While all individual centers decreased overall median DAP/kg, the use of novel devices for ASD closure correlated with a temporary period of worsening institutional radiation exposure and increased fluoroscopy time. The introduction of new ASD closure devices resulted in increased radiation exposure during a QI project designed to reduce radiation exposure. Therefore, outcome assessment must be contextualized in QI projects, hospital evaluation, and public reporting, to acknowledge the expected variation during innovation and introduction of novel therapies.


Assuntos
Comunicação Interatrial , Exposição à Radiação , Dispositivo para Oclusão Septal , Cateterismo Cardíaco/métodos , Fluoroscopia/métodos , Comunicação Interatrial/cirurgia , Humanos , Melhoria de Qualidade , Doses de Radiação , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos , Resultado do Tratamento
19.
Biomedicines ; 9(5)2021 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-33925558

RESUMO

Bioabsorbable materials made from polymeric compounds have been used in many fields of regenerative medicine to promote tissue regeneration. These materials replace autologous tissue and, due to their growth potential, make excellent substitutes for cardiovascular applications in the treatment of congenital heart disease. However, there remains a sizable gap between their theoretical advantages and actual clinical application within pediatric cardiovascular surgery. This review will focus on four areas of regenerative medicine in which bioabsorbable materials have the potential to alleviate the burden where current treatment options have been unable to within the field of pediatric cardiovascular surgery. These four areas include tissue-engineered pulmonary valves, tissue-engineered patches, regenerative medicine options for treatment of pulmonary vein stenosis and tissue-engineered vascular grafts. We will discuss the research and development of biocompatible materials reported to date, the evaluation of materials in vitro, and the results of studies that have progressed to clinical trials.

20.
J Perinatol ; 41(7): 1528-1539, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33674714

RESUMO

Primary pulmonary vein stenosis (PPVS) is an emerging problem among infants. In contrast to acquired disease, PPVS is the development of stenosis in the absence of preceding intervention. While optimal care approaches remain poorly characterized, over the past decade, understanding of potential pathophysiological mechanisms and development of novel therapeutic strategies are increasing. A multidisciplinary team of health care providers was assembled to review the available evidence and provide a common framework for the diagnosis, management, and treatment of PPVS during infancy. To address knowledge gaps, institutional and multi-institutional approaches must be employed to generate knowledge specific to ex-premature infants with PPVS. Within individual institutions, creation of a team comprised of dedicated health care providers from diverse backgrounds is critical to accelerate clinical learning and provide care for infants with PPVS. Multi-institutional collaborations, such as the PVS Network, provide the infrastructure and statistical power to advance knowledge for this rare disease.


Assuntos
Doenças do Prematuro , Veias Pulmonares , Estenose de Veia Pulmonar , Constrição Patológica , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...